Ferro fundidoglobovalve is a forced-sealing valve, so when the valve is closed, pressure must be applied to the disc to force the sealing surface to not leak. When the medium enters the valve from below the disc, the resistance that the operating force needs to overcome is the friction force of the valve stem and packing and the thrust generated by the pressure of the medium. The force to close the valve is greater than the force to open the valve, so Ferro fundidoThe diameter of the valve stem of the globovalve should be large, otherwise the valve stem will bend up failure.
2. Parameters of Ferro fundidoGloboValve
Tipo de Válvula
Ferro fundidoglobovalve
DN
DN10~DN600
PN(MPaï¼ ‰
1,6~16Mpa
Faixa de temperatura do projeto
-15â „ƒï½ž200â„ ƒ
Tipo de conexão:
Flangeado
Tipo de atuador
Acionamento manual, atuador pneumático, hidráulico ou elétrico
Meio Aplicável
Água, óleo, gás e vários meios de corrosão
Peças de reposição
Material
Disco de cobertura do corpo
Aço forjado, aço fundido
Tronco
Aço forjado, aço fundido
Embalagem
Grafite Flexível, Grafite Flexível Aprimorada, PTEE
Calço de vedação
Grafite Flexiblo aprimorada, aço inoxidável, PTFE
Selando rosto
13Cr,STL, PTFE, Nylon, com material do corpo
3. Advantages of Ferro fundidoglobovalve
1) The structure of the Ferro fundidoglobovalve is simpler than that of the gate valve, and it is more convenient to manufacture and maintain.
2) A superfície de vedaçãoof Ferro fundidoglobovalve is not easy to wear and scratch, and the sealing performance is good. There is no relative sliding between the valve disc and the sealing surface of the valve body when opening and closing, so neither abrasion nor abrasion is serious. The sealing performance is good and the service life is long. .
3) When the Ferro fundidoglobovalve is opened and closed, the disc stroke is small, so the height of the shut-off valve is smaller than that of the gate valve, but the structure length is longer than that of the gate valve.
4) Ferro fundidoglobovalve has a large opening and closing moment, which is laborious and takes a long time.
5) The medium channel in the Ferro fundidoglobovalve is tortuous, the fluid resistance is large, and the power consumption is large.
6) When the nominal pressure of the medium flow direction of the Ferro fundidoglobovalve PN≤16MPa, the downstream flow is generally adopted, and the medium flows upward from the bottom of the valve flap; when the nominal pressure PN≥20MPa, the reverse flow is generally adopted, and the medium flows downward from the top of the valve flap. In order to increase the seal performance. When in use, the shut-off valve medium can only flow in one direction and cannot change the direction of flow.
7) The valve flap is often eroded when the Ferro fundidoglobovalve is fully opened.
4. FAQ